CZ1334 Explosion-proof loda isolation switch
CZ1334 Explosion-proof loda isolation switch
Ex mark:Ex de ⅡC T6/T5 Gb DIP A21 TA,T6/T5
Intended use:zone 1 ,zone 2,zone21,zone22
Ambient temperature use: -40℃≤ Ta≤ 40℃/55℃
Degree of protection:IP66
Rated current:16A(690V AC)/25A(400V AC) Terminal:2*6mm2
Capacity of switch:AC 3 230V 25A 400V 25A 500V 20A 690V16A
Material of enclosure:304 316L Stainless steel
Weight:3Poles:2.51kg 4Poles:2.51kg
CZ1300 stainless steel Explosion-proof terminal box
CZ1300 stainless steel Explosion-proof terminal box
Ex mark:Ex e ⅡT5/T6 DIP A21 TA, T5/T6 (Ex e)
Ex ia/ibⅡA ⅡB ⅡC T6 DIP A20 TA,T6 (Ex i)
Intended use:Can be used in zone 0,zone 1 and zone 2,Can be used in zone20,zone 21 and zone 22
Degree of protection:IP66
Ambient temperature:-40℃≤Ta≤50℃(40℃)
Material:304,316
CZ0512 Explosion-proof thermorelay module
CZ0512 Explosion-proof thermorelay module
Ex mark:Ex Ⅱ2G Ex de Ⅱ C Gb
Intended use:Can be used in zone 1 ,zone 2,zone21,zone22
Ambient temperature use:-40℃≤Ta≤70℃
Rater voltage:690V Rated current:up to 38A
Setting range of over loda trip:up to 38A
Rated voltage of aux.contact:690V,Rated current of aux.contact:5A
Terminals:main contacts 1~10mm2(6~10mm2 used in connection with comperssion lug) Auxiliary contact 1~2.5mm2
Material of enclosure:Unsaturated resin
CZ0240 Full plastic Explosion-proof controller
CZ0240 Full plastic Explosion-proof controller
Ex mark:Ex Ⅱ2GD Ex de ⅡC T6 Ex tD A21 T 80℃
Intended use:Can be used in zone 1,zone 2,zone21,zone22,Ambient temperature use:-40℃≤Ta≤40℃
Degree of protection:IP66,Reted voltage:250V Rated current:max16A
Component terminal:2.5m㎡ PE terminals:4m㎡
Material of enclosure:Alloy plastic of static resistence
Cable entry:CZ0240/1、2、3,Molded plastic 1xM20, cable outer diameter Φ5.5~13mm.CZ0240/5、6,Molded plastic 2xM25,cable outer diameterΦ8~17mm
CZ0511 Explosion-proof creep age breakers module
CZ0511 Explosion-proof creep age breakers module
Ex mark:Ex Ⅱ2G Ex de Ⅱ C Gb
Intended use:Can be used in zone 1 ,zone 2,zone21,zone22
Ambient temperature use:-40℃≤Ta≤70℃
Rated voltage:230/400V,50Hz
Rated current:Max 40A
Rated remained action current:10,30,300mA
Rated on-off capacity:6kA,10kA
Trip character:C、D Characteristic curve
Number of poles:1P+N
Terminals:main contacts1~10mm2(6~10mm2 used in connection with compression lug)
Weight:1.1kg
M0251 Full plastic weather-proof plugs and sockets 16A 3P
M0251 Full plastic weather-proof plugs and sockets 16A 3P
Corrosion-proof mark:WF2
Ambient temperature use:-40℃≤Ta≤40℃
Degree of protection:IP66
Frequency:50/60Hz
Rated voltage:3Pole up to 400V~
Rated current:maximum 16A
Switch capacity:AC3 up to 400V/16A
Cable entry:Wall type socket(bottom)1xM25 Φ8~17mm
See page C1/06 for other forms
Plug:Cable outside diameter Φ6~15mm
Coupler type:Cable outside diameter Φ6~15mm
CZ1332 Explosion-proof motor protection switches
CZ1332 Explosion-proof motor protection switches
Ex mark:Ex de ⅡC T6/T5/T4 Gb / Ex de ⅡB T6/T5/T4 Gb DIP A21 TA,T6/T5/T4
Intended use:zone 1 ,zone 2,zone21,zone22
Ambient temperature use:-20℃≤Ta≤55℃ -40℃≤ Ta≤ 55℃
Degree of protection:IP66.Rated voltage:440V
Setting range of over load trip:0.1~25A
AC3 motor on-off capacity:440V/25A Cross section of terminal:2*10mm2 2*2.5mm2
Capacity of auxiliary contact:AC15 1A/230V
Voltage trip:230V/50Hz.Cable enties:(0.1-16A 2*M25 Φ8-1
CZ0581 Full Plastic Explosion-proof magnetic starter
CZ0581 Full Plastic Explosion-proof magnetic starter
Ex mark:Ex de ⅡC T5(Ta≤+40℃)/T4(Ta≤+55℃)Gb DIP A21 TA,T5(Ta≤+40℃)/T4(Ta≤+55℃) Intended use:Can be used in zone 1 ,zone 2,zone21,zone22
Ambient temperature use:-40℃≤Ta≤55℃
Degree of protection:IP65.Rater voltage:690V .Rated current:38A
On-off capacity:AC3/4~18.5kW.Coil voltage:AC24V 36V 48V 110V 220~230V 380~400V
Cable entires:(6~24A) 3×M25 Φ8-17mm (23~38A)3×M32 Φ12-21mm
Material of enclosure:Anti-static glass fibre reinforced polyeste

Top articles

Latest articles

Your browsing history

    Loading...

CZ Explosion-proof passed IECEx Certificate Personnel Competence on 30th Jan 2016 from TUV

Categories: Company AlbumStars: 5Stars Visit: - Release time: 2017-01-10 16:54:00
Font size:【 Large Middle Small

CZ passed IECEx Certificate Personnel Competence on 30th Jan 2016 from TUV

CZ Explosion-proof passed IECEx Certificate Personnel Competence on 30th Jan 2016 from TUV

Information about ""